Model / Specification

T-60A

T-60B

T-60C

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

DC output voltage

5V

12V

-5V

5V

12V

-12V

5V

15V

-15V

Output voltage error (Note2)

±2%

±6%

±6%

±2%

±6%

±6%

±2%

±6%

±6%

Rated output current

5A

2.5A

0.5A

5A

2.5A

0.5A

5A

2A

0.5A

Output current rage

0.5-7A

0.2-3.5A

0-1A

0.5-7A

0.2-3.5A

0.1-1A

0.5-7A

0.2-3A

0-1A

Wave and noise(Note3)

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±1%

±0.5%

±0.5%

±1%

±0.5%

±0.5%

±1%

±0.5%

Load stability(Note5)

±1%

±4%

±1%

±1%

±4%

±1%

±1%

±4%

±1%

DC output power

57.5W

61W

62.5W

Efficiency

72%

72%

72%

Adjustable range for DC voltage

CH1+10,-5%

CH1+10,-5%

CH1+10,-5%

AC input voltage range

85264VAC 4763Hz; 120370VDC

Input current

2A/115V 1A/230V

AC impulse current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

105%150% TypePULSING HICCUP SHUTDOWN Reset. auto recovery

Over-voltage protection

CH1:5.756.75V

High-temperature protection

……

Temperature coefficient

±0.03%(050) ON+5V OUTPUT

Setup rise hold up time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC

Vibration

10500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval3KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95%RH

Overall dimension

159*97*38mm

Weight

0.56Kgs

Safety standards

Meet UL1950

EMC standards

Meet IEC801-2,3,4,IEC555-2

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.