Model / Specification

T-30A

T-30B

CH1

CH2

CH3

CH1

CH2

CH3

DC output voltage

5V

12V

-5V

5V

12V

-12V

Output voltage error (Note2)

±2%

+2,-6%

+2,10%

±2%

+2,-6%

±6%

Rated output current

3A

1A

0.5A

3A

1A

0.5A

Output current rage

0.5-3A

0.1-1A

0.1-0.5A

0.5-3A

0.1-1A

0.1-0.5A

Wave and noise(Note3)

50mVp-p

100mVp-p

50mVp-p

50mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±1%

±1%

±0.5%

±1%

±1%

Load stability(Note5)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

30W

33W

Efficiency

70%

72%

Adjustable range for DC voltage

CH1+10,-5%

CH1+10,-5%

AC input voltage range

85132VAC/170264VAC selected by switch 4763Hz;240370VDC

Input current

0.8A/115V 0.45A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5A/240VAC

Overload protection

105%150% TypeFOLDBACK Pulsing hiccup shutdown Reset. auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03%(050) ON+5V OUTPUT

Setup rise hold up time

200ms,100ms,30ms

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval1.5KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure0500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95%RH

Overall dimension

129*98*38mm

Weight

0.4Kgs

Safety standards

Meet UL1012 requirement(not apply for the mark)

EMC standards

Meet FCC Part 15J Conduction class A

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.