You are here: Home >> Industries & Products >> Switching Power Supply >> S series >> S-150 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
S-150 Switching Power Supply
S-150 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Product Description:

Model / Specification

S-150-5

S-150-7.5

S-150-9

S-150-12

S-150-13.5

S-150-15

S-150-24

S-150-27

S-150-48

DC output voltage

5V

7.5V

9V

12V

13.5V

15V

24V

27V

48V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

30A

20A

16.7A

12.5A

11.2A

10A

6.5A

5.6A

3.2A

Output current rage

0-30A

0-20A

0-16.7A

0-12.5A

0-11.2A

0-10A

0-6.5A

0-5.6A

0-3.2A

Wave and noise(Note3)

150mVp-p

150mVp-p

180mV

180mV

180mV

180mV

240mV

240mV

240mV

Inlet stability(Note4)

±0.5%

±0.5%

±0.3%

±0.3%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

Load stability(Note5)

±0.5%

±0.5%

±0.3%

±0.3%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

DC output power

150W

150W

150.3W

150W

151.2W

150W

156W

151.2W

153.6W

Efficiency

78%

80%

80%

82%

83%

84%

85%

86%

87%

Adjustable range for DC voltage

4.5-5.5V

6-8.3V

8-10.4V

10.6-13.2V

12-15V

13.5-16.5V

21-28V

24-30V

43-53V

AC input voltage range

85132VAC/176264VAC SELECTED BY JUMPER OR SWTCH 4763Hz;255370VDC

Input current

3.2A/115V 1.6A/230V

AC impulse current

Cold-start current 35A/115V 60A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105150 TypePULSING HICCUP SHUTDOWN Reset:auto recovery

Over-voltage protection

115%135%

High-temperature protection

……

Temperature coefficient

±0.03%(050)

Setup rise hold up time

100ms,50ms,20ms

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval3KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95RH

Overall dimension

199*110*50mm

Weight

0.8Kgs

Safety standards

Meet UL1012,TUV EN60950

EMC standards

Meet CLSPR22(EN55022), IEC801-2,3,4,IEC555-2 Verification

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.

SendMessage