You are here: Home >> Industries & Products >> Switching Power Supply >> S series >> S-145 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
S-145 Switching Power Supply
S-145 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Product Description:

Model / Specification

S-145-5

S-145-7.5

S-145-12

S-145-24

DC output voltage

5V

7.5V

12V

24V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

Rated output current

25A

18A

12A

6A

Output current rage

0-25A(Biggest 30A)

0-18A(Biggest 21A))

0-12A(Biggest 14A)

0-6A(Biggest 7A))

Wave and noise(Note3)

100mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.3%

±0.2%

Load stability(Note5)

±0.5%

±0.5%

±0.3%

±0.2%

DC output power

125W

135W

144W

144W

Efficiency

78%

80.5%

80.5%

83.5%

Adjustable range for DC voltage

4.75-5.5V

6-8V

10.8-13.2V

21-28V

AC input voltage range

85132VAC/180264VACselected by switch 4763Hz;255370VDC

Input current

3.2A/115V 1.6A/230V

AC impulse current

Cold-start current 35A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

125%165%Type:pulsing hiccup shutdown Reset: auto recovery

High-temperature protection

……

Temperature coefficient

±0.03%(050)

Setup rise hold up time

200ms,100ms,30ms

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval1.5KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95RH

Overall dimension

199*98*38mm

Weight

0.7Kgs

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

EMC standards

Meet FCC Part 15J Conduction Class B

Note1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity 

2.Error,include the setting error, line stability and load stability.(Note:5)
3Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.

SendMessage