You are here: Home >> Industries & Products >> Switching Power Supply >> NE series >> NES-100 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
NES-100 Switching Power Supply
NES-100 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Specification:

Model

NES-100-5

NES-100-7.5

NES-100-9

NES-100-12

NES-100-15

NES-100-24

NES-100-48

Output

DC output voltage

5V

7.5V

9V

12V

15V

24V

48V

Rated output current

20A

13.6A

11.2A

8.5A

7A

4.5A

2.3A

Output current range

0-20A

0-13.6A

0-11.2A

0-8.5A

0-7A

0-4.5A

0-2.3A

Rated output power

100W

102W

100.8W

102W

105W

108W

110.4W

Wave and noise

80mVp-p

120mVp-p

120mVp-p

120mVp-p

120mVp-p

120mVp-p

150mVp-p

Voltage adjustment range

4.75-5.5V

7.13-8.3V

8.55-9.9V

11.4-13.2V

14.25-16.5V

22.8-26.4V

45.6-52.8V

Voltage accuracy

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Linear adjust rate

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Over-load adjust rate

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Set up, rise time

500ms,20ms/230VAC 500ms,20ms/115VAC(full load)

Hold up time

30ms/230VAC 25ms/115VAC (full load)

Input

Input voltage range

85-132VAC or 248-373VAC Or 176-264VAC

Frequency range

47-63Hz

Efficiency

80%

81%

81%

83%

84%

86%

86%

AC current

2A/115VAC 1.2A/230VAC

Inrush current

Cold-start 36A

Leakage current

2mA/240VAC

Protection

 

Overload protection

Rated output power 110%150% set overload protection

Protection typepulsing hiccupshut down abnormal condition. auto recovery

Over-voltage protection

5.75-6.75V

8.6-10.1v

10.4-12.2V

13.8-16.2V

17.25-20.25V

27.6-32.4v

55.2-64.8v

Protection typepulsing hiccup, shut down voltage abnormal condition. auto recovery

Condition

 

Working temperature

-20+60 (Reference derating curve)

Working humidity

2090RH (No Condensation)

Store temperature and humidity

-40+85;10%95%RH

Temperature factor

±0.03%/0-45

shock resistance

10500Hz2G 10min./1cycleperiod for 60 minXYZ axes

Safety and electromagnetic compatibility

 

Safety standard

UL60950-1,CB(EN60950)-1, pass GB4943

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC

Electromagnetic interference

EN55022(CISPR22) Class B, GB9254 Class

Harmonic current

EN61000-3-2,-3

Electronmagnetic stamina

EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1

Others

MTBF

≥320.72Khrs, MIL-HDBK-217F(25)

Measurement

159*97*38mm(L*W*H)

Packing

0.55k.g30pcs,17.5k.g/0.97CUFT

Notes

1. The testing condition for the parameter above is:230VAC input, rated load,25
2. Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 
3. Error,include the setting error, current regulation and voltage regulation 
4.Linear adjust rate test method: under rated over-load, From low voltage to high voltage 
5.Over-load adjustment rate test method: from 20%-100% rated over-load , others output under 60% .
6.Inner components include power supply, Combined with the electromagnetic compatibility test

SendMessage